smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.4.57-calculate] (local build)
2
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
3
4
=== START OF INFORMATION SECTION ===
5
Device Model:     ST6000DM003-2CY186
6
Serial Number:    WCT3GWT5
7
LU WWN Device Id: 5 000c50 0d012fe93
8
Firmware Version: 0001
9
User Capacity:    6,001,175,126,016 bytes [6.00 TB]
10
Sector Sizes:     512 bytes logical, 4096 bytes physical
11
Rotation Rate:    5425 rpm
12
Form Factor:      3.5 inches
13
Device is:        Not in smartctl database [for details use: -P showall]
14
ATA Version is:   ACS-3 T13/2161-D revision 5
15
SATA Version is:  SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
16
Local Time is:    Wed Sep 30 15:59:54 2020 +08
17
SMART support is: Available - device has SMART capability.
18
SMART support is: Enabled
19
20
=== START OF READ SMART DATA SECTION ===
21
SMART overall-health self-assessment test result: PASSED
22
23
General SMART Values:
24
Offline data collection status:  (0x00)	Offline data collection activity
25
					was never started.
26
					Auto Offline Data Collection: Disabled.
27
Self-test execution status:      (   0)	The previous self-test routine completed
28
					without error or no self-test has ever 
29
					been run.
30
Total time to complete Offline 
31
data collection: 		(    0) seconds.
32
Offline data collection
33
capabilities: 			 (0x73) SMART execute Offline immediate.
34
					Auto Offline data collection on/off support.
35
					Suspend Offline collection upon new
36
					command.
37
					No Offline surface scan supported.
38
					Self-test supported.
39
					Conveyance Self-test supported.
40
					Selective Self-test supported.
41
SMART capabilities:            (0x0003)	Saves SMART data before entering
42
					power-saving mode.
43
					Supports SMART auto save timer.
44
Error logging capability:        (0x01)	Error logging supported.
45
					General Purpose Logging supported.
46
Short self-test routine 
47
recommended polling time: 	 (   1) minutes.
48
Extended self-test routine
49
recommended polling time: 	 ( 764) minutes.
50
Conveyance self-test routine
51
recommended polling time: 	 (   2) minutes.
52
SCT capabilities: 	       (0x30a5)	SCT Status supported.
53
					SCT Data Table supported.
54
55
SMART Attributes Data Structure revision number: 10
56
Vendor Specific SMART Attributes with Thresholds:
57
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
58
  1 Raw_Read_Error_Rate     0x000f   081   064   006    Pre-fail  Always       -       128320943
59
  3 Spin_Up_Time            0x0003   095   094   000    Pre-fail  Always       -       0
60
  4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       11
61
  5 Reallocated_Sector_Ct   0x0033   100   100   010    Pre-fail  Always       -       0
62
  7 Seek_Error_Rate         0x000f   072   060   045    Pre-fail  Always       -       15518587
63
  9 Power_On_Hours          0x0032   100   100   000    Old_age   Always       -       475 (236 112 0)
64
 10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
65
 12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       10
66
183 Runtime_Bad_Block       0x0032   100   100   000    Old_age   Always       -       0
67
184 End-to-End_Error        0x0032   100   100   099    Old_age   Always       -       0
68
187 Reported_Uncorrect      0x0032   100   100   000    Old_age   Always       -       0
69
188 Command_Timeout         0x0032   100   100   000    Old_age   Always       -       0
70
189 High_Fly_Writes         0x003a   100   100   000    Old_age   Always       -       0
71
190 Airflow_Temperature_Cel 0x0022   060   049   040    Old_age   Always       -       40 (Min/Max 33/50)
72
191 G-Sense_Error_Rate      0x0032   100   100   000    Old_age   Always       -       0
73
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       6
74
193 Load_Cycle_Count        0x0032   100   100   000    Old_age   Always       -       62
75
194 Temperature_Celsius     0x0022   040   051   000    Old_age   Always       -       40 (0 32 0 0 0)
76
195 Hardware_ECC_Recovered  0x001a   081   064   000    Old_age   Always       -       128320943
77
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
78
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
79
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
80
240 Head_Flying_Hours       0x0000   100   253   000    Old_age   Offline      -       269 (142 163 0)
81
241 Total_LBAs_Written      0x0000   100   253   000    Old_age   Offline      -       20191236159
82
242 Total_LBAs_Read         0x0000   100   253   000    Old_age   Offline      -       6631857933
83
84
SMART Error Log Version: 1
85
No Errors Logged
86
87
SMART Self-test log structure revision number 1
88
No self-tests have been logged.  [To run self-tests, use: smartctl -t]
89
90
SMART Selective self-test log data structure revision number 1
91
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
92
    1        0        0  Not_testing
93
    2        0        0  Not_testing
94
    3        0        0  Not_testing
95
    4        0        0  Not_testing
96
    5        0        0  Not_testing
97
Selective self-test flags (0x0):
98
  After scanning selected spans, do NOT read-scan remainder of disk.